Guidelines for Underfloor Heating

The following is not intended to be a comprehensive checklist, rather, a guide for some important considerations when choosing specific types of heating options for underfloor heating solutions.

Rules that apply to all heaters

No heater is to be run underneath an object/furniture with a flat base that sits on the floor as it will trap the heat and cause a hot joint.  It is not advised to run them beneath vanities or similar even if they don't have a flat base. 

Replacement of vanities, toilets and other bathroom fixtures are not covered by manufacturers warranty if the heaters are run beneath them

Cables/mats can't be overlapped!  Controllers need to be adjacent to the mats as the thermostat probes cannot be lengthened.


Floor heating type: Mats - which are laid beneath tiled floors and in concrete slabs

  • Mats can't be shortened so they need to be the correct size or smaller than the room
  • Toilets, vanities, spa's etc their area needs to be subtracted from the floor size
  • Floor needs to be water proofed and spotless for the mat to stick to it
  • Mats work best above the scree.  Placing them beneath the scree will make the heating inefficient and may not result in proper heating, not to mention, costly
  • Floors need to be marked as to where the vanity, toilet etc are being located before the mat can be laid
  • Conduit from the controller position to the floor coming out 1 inch into the scree (Groove in scree is required) with draw wires installed.  This needs to be installed before walls and water proofing is installed

 

Floor heating type: Loose wire - used for tiled or concrete floors

  • These heaters go inside the scree
  • An  amount of extra wire can be bunched at 50mm spacing rather than 100mm to use up extra length but this is labour intensive
  • Floors also need to be marked up so it is known where bathroom furniture will be located
  • Cable length should be as close to the correct size as possible to reduce labour
  • Mat is laid before the scree is laid.
  • Conduits from the controller position to the floor coming out 1 inch into the scree with draw wires. This needs to be installed before walls and water proofing are done.
  • Room needs to be clear of debris before laying
  • When measuring size of heater, subtract furnishings, drains etc from the size of the room

 

Floor heating type: Foil heaters - for wooden or carpeted floors etc

  • When laid on a wooden floor, a vapour lock seal is required to stop the wood from sweating and buckling
  • Mats can't be shortened so they need to be the correct size or smaller than the room
  • Foil mats need a gap of 150mm-200mm from the edge of the room so that the carpet layer can do their job. This needs to be considered when measuring up room sizes.
  • There are also insulating mats (stops heat being lost through the bottom of the floor), which can be considered depending on the floor type (concrete slab, wooden floor etc)
  • Rooms need to be clear of furniture and debris
  • Earthing continuity is important when laying these mats
  • Furniture needs to be marked out on the floor so that mat isn't laid where it will be damaged
  • Provisions must be in place to get the cold tails and temperature probe to the controller before the walls are patched etc.

 

Please note that the information above are broad guidelines only and no liability is under taken for anyone installing underfloor heating without proper qualifications.  Each job must be reviewed with respect to its specific conditions.

For more information and the best solution for your underfloor heating needs, contact Simon Caddy Electrical or call 0400 11 00 81

Download your guide on
how to make your home
'electrically safe’.

Happy Clients

We are very impressed with the service given. T...

Maureen Disney
Read all

Why choose us

  • We pride ourselves on our excellent communication skills with our clientele and within our team.
  • We strive for a high standard of workmanship and electrical safety, abiding by all Australian standards for the services we provide.
  • We are a Master Electricians Australia Member. By choosing us you are choosing a quality electrical contractor who has proven they have the experience to provide you with a safe, energy efficient solution for your home or business.
  • We deliver on time service with a smile for a fair price with a 12-month guarantee on our work.

Latest News

Read All

All you need to know about decorative lighting

Posted by Simon Caddy Electrical on 6 July 2017
All you need to know about decorative lighting
Light can transform moods and the whole environment around you.  With shades of light, the whole ambience of the room can be changed fr...
Posted in:Electrical ServicesDecorative Lighting  

Smart meters - do I need one?

Posted by Simon Caddy Electrical on 6 July 2017
Smart meters - do I need one?
You may have heard of smart meters, but what exactly are they and how do they work?  Even more important, should you install one? Read ...
Posted in:Energy EfficiencySmart DevicesSaving Power  

Should your business have a back-up generator or UPS?

Posted by Simon Caddy Electrical on 6 July 2017
Should your business have a back-up generator or UPS?
There are few things that are more disruptive to a business than interrupted power supply. Whether your business relies on computers alone o...
Posted in:Smart DevicesElectrical ServicesSaving Power  

The pros and cons for going solar

Posted by Simon Caddy Electrical on 5 June 2017
The pros and cons for going solar
Solar energy is, simply, energy provided and produced by the sun. This energy is in the form of solar radiation, which makes the production of s...
Posted in:Energy EfficiencySaving Power  

Contact us now

click here

Request a quote

click here
Domestic - Commercial - Industrial - "Nothing's Impossible"